EN
PATTERN
PATTERN GES48160M300-500XP front product view

Solar Inverters

16kW 120/240V Split-Phase Hybrid Inverter

GES48160M300-500XP · 16,000W · 120/240Vac split-phase · 51.2V battery · Dual MPPT

GES48160M300-500XP · 16kW · 51.2V · 120/240Vac
Rated Output
16,000W model rating — split-phase system
Nominal Battery Voltage
51.2Vdc (48V-class system)
AC Output
120/240Vac · split-phase · L1+L2+N+PE
  • 16,000W rated model with 120/240Vac split-phase output and a colour touch screen.
  • Two MPPT channels support 12,000W per channel, 24,000W total PV input, and 90–450V tracking.
  • Maximum battery charging current 300A and continuous discharge current 340A; battery-bank design must match the current demand.
  • Up to six units in an approved parallel system; 96kW is the aggregate nominal figure for six 16kW units.
  • CT anti-backflow, AC coupling, tariff management and dry-contact generator control are listed in the supplied datasheet.
  • 10ms typical transfer, solar + grid battery-less operation and USB/RS485/WiFi/CAN communication.

Technical Specifications

ModelGES48160M300-500XP
Rated Output16,000W model rating — split-phase system
AC Output120/240Vac · split-phase · L1+L2+N+PE
Nominal Battery Voltage51.2Vdc (48V-class system)
Maximum PV input power12,000W + 12,000W = 24,000W
Maximum PV input voltage500V
PV input / MPPT voltage range90–450V
Maximum MPPT input current36A + 36A
Maximum PV charging current300A
AC input voltage range, per phase85–140Vac
AC input frequency range47–55Hz / 57–65Hz
Maximum AC input current, per phase90Aac
Maximum AC charging current200Adc
Maximum battery charge / discharge current300A / 340A
Maximum efficiency, battery to load>93.5%
Grid breaker rating100A
Dimensions (datasheet order)720 × 482 × 149mm
Weight37.5kg
Communication portsUSB / RS485 / WiFi / CAN
AC couplingYes; configuration and local interconnection requirements apply
DisplayColour touch screen
Output rating clarificationConfirm allowable load per 120V leg and imbalance limits in writing; the supplied sheet uses ambiguous per-phase / same-phase labels.
PV start voltage120V
MPPT channels2
Output frequency50/60Hz
Power factor1
Minimum battery start voltage44V
Battery operating / charge voltage range40–60Vdc
Battery typesLead-acid / lithium; charging settings and BMS compatibility must be confirmed
Grid overload protectionCircuit breaker
Battery short-circuit protectionFuse
AC reverse-feed protectionYes — CT configuration and installation requirements apply
AC output short-circuit / wiring protectionYes
Transfer time10ms typical; critical-load suitability requires system assessment
Operating temperature−10°C to 55°C; derating above 45°C
Storage temperature−25°C to 60°C
Humidity range5%–95%
CoolingForced-air cooling, variable speed
Protection classIP21 — indoor installation
Noise≤60dB
Altitude4,000m maximum; no derating at or below 2,000m
Parallel units1 to 6; approved model combinations, firmware and wiring required
Dry-contact generator controlYes
Battery-less operationYes — solar + grid operating mode
Remote diagnostics / OTAListed in supplied datasheet; confirm enabled configuration
CT anti-backflowYes; not a substitute for utility interconnection approval
Warranty2 years; applicable warranty terms govern

Applications

  • ·Residential solar self-consumption and essential-load backup
  • ·Distributor and installer projects with model-matched battery banks
  • ·Generator-assisted storage systems using supported control modes

OEM / ODM & Packaging

Send model, quantity, target country, battery requirements and branding files for a wholesale or OEM quotation. Lithium battery compatibility and destination approvals require a model-specific review.

Confirm export packing dimensions, gross weight, included accessories and shipping terms in the quotation. Inverter warranty: 2 years under the applicable warranty policy.

FAQ

16kW 120/240V Split-Phase Hybrid Inverter — Frequently Asked Questions

What is the difference between this and a 120V single-phase inverter?

GES48160M300-500XP supplies 120/240Vac split-phase service with L1, L2, neutral and protective earth. A 120V single-phase inverter supplies one line and neutral. Match the site service and load distribution before selecting a model.

Can one standard home battery support the full 16kW output?

Do not assume so. This model lists 340A continuous battery discharge. Confirm bank voltage, aggregate continuous current, BMS communication, cabling and protection. A battery peak-current figure alone does not establish continuous power compatibility.

How is the 24kW solar input divided?

The supplied datasheet lists two MPPT channels at 12,000W and 36A per channel, 24,000W total. Maximum PV voltage is 500V and the tracking range is 90–450V. Check cold-weather string open-circuit voltage and channel current.

How many inverters can be paralleled?

The supplied datasheet lists up to six units. Six times 16kW equals 96kW aggregate nominal power, subject to approved wiring, compatible firmware, battery current and site design.

Can I load one 120V leg to 16kW?

Do not infer this from the headline model rating. The supplied sheet has ambiguous per-phase and same-phase labels. Request written confirmation of per-leg power, allowable imbalance and the intended wiring arrangement before design approval.

Does CT anti-backflow or AC coupling prove grid approval?

No. These are operating functions. Obtain the exact model certificate and confirm local electrical and utility requirements before any grid-connected installation or export arrangement.

Where do I get pricing, original specifications and installation support?

Download the supplied GES48160M300-500XP PDF on this page. Send the destination, quantity, load list, AC service, PV design and battery specification to info@patternbattery.com or use the enquiry form.

Related Products

You May Also Need

PATTERN SPI4865M150-300P front product view

Solar Inverters

6.5kW 48V 120V Single-Phase Hybrid Inverter

SPI4865M150-300P 6.5kW 120V hybrid inverter: 48V battery, 9kW dual MPPT, up to 6 parallel units. View specifications and download the PDF.

PATTERN SPI2436M120-500 3.6kW 24V single-phase hybrid inverter — front view

Solar Inverters

3.6kW 24V 120V Single-Phase Hybrid Inverter

PATTERN SPI2436M120-500: 3,600W residential hybrid inverter with 120Vac single-phase output, 24V-class battery input and up to 6,000W PV input.

PATTERN SPI4836M80-300P 3.6kW 48V single-phase hybrid inverter — front view

Solar Inverters

3.6kW 48V 120V Single-Phase Hybrid Inverter

PATTERN SPI4836M80-300P: 3,600W residential hybrid inverter with 120Vac single-phase output, 48V battery input and up to 6,000W PV input.

PATTERN PT-TM1512 low-frequency inverter

Solar Inverters

PT-TM1512 Low-Frequency Solar Inverter

PATTERN PT-TM1512 low-frequency solar inverter for off-grid and backup power projects. See the model datasheet for electrical specifications.

PATTERN Is Looking for Home Energy Storage Distributors Worldwide

Reliable products, factory supply and technical support for local distributors and installers.

Become Our Distributor