MPPT Solar Charge Controllers
MPK7-8048 · 80A battery charging · 12V / 24V / 36V / 48V · Model-specific PV and load limits
| Model | MPK7-8048 |
| Rated Charge Current | 80A |
| System Voltage | 12V / 24V / 36V / 48V / Auto; confirm lithium setup before use |
| Maximum PV open-circuit voltage | Below 200V at the lowest design temperature; below 180V at 25°C |
| Minimum PV voltage, 12V / 24V / 36V / 48V system | 20V / 40V / 60V / 80V |
| Maximum PV input power at 12V battery | 1,040W |
| Maximum PV input power at 24V battery | 2,080W |
| Maximum PV input power at 36V battery | 3,120W |
| Maximum PV input power at 48V battery | 4,160W |
| Rated load / discharge current | 40A — separate from the rated battery charge current |
| Self-consumption | Approximately 35mA at 48V |
| Published MPPT tracking accuracy | 99% maximum; actual performance depends on conditions |
| Published maximum charging efficiency | 97%; not the same measurement as MPPT tracking accuracy |
| Charging control | Multi-stage: MPPT, absorption, float, equalization, CV; use battery-approved settings |
| Float-charge preset, 12V / 24V / 36V / 48V | 13.8V / 27.6V / 41.4V / 55.2V |
| Absorption-charge preset, 12V / 24V / 36V / 48V | 14.4V / 28.8V / 43.2V / 57.6V |
| Equalization preset, 12V / 24V / 36V / 48V | 14.6V / 29.2V / 43.8V / 58.4V; disable where not permitted by the battery |
| Load disconnect preset (LVD) | 10.8V / 21.6V / 32.4V / 43.2V |
| Load reconnect preset (LVR) | 12.6V / 25.2V / 37.8V / 50.4V |
| Load-control modes | Normal, light control, light and timing control, timing control, reverse light control |
| Light-control voltage presets | 5V / 10V / 15V / 20V |
| Battery profiles | GEL, SLD, FLD and USER; lithium requires suitable custom charging parameters |
| Display | Backlit colour LCD, 3 buttons |
| Cooling | Aluminium-alloy heatsink and cooling fan |
| Terminal capacity | Copper terminals, ≤25mm² as listed; final conductor and protection sizing must be engineered for the installation |
| Temperature probe | 3m lead listed in supplied sheet |
| Communication | RS485 via RJ45 port |
| Operating temperature | −20°C to +55°C; derate if permitted ambient temperature is exceeded |
| Storage temperature | −30°C to +80°C |
| Humidity | 10%–90%, non-condensing |
| Product dimensions | 265 × 220 × 100mm |
| Warranty | 2 years; applicable model-specific warranty terms govern |
Provide the required model, quantities, battery settings, destination and private-label artwork for wholesale or OEM review. Confirm lithium settings and any monitoring accessories in the quotation.
Request model-specific packing dimensions, shipment weight and accessory list. Confirm lead time and freight terms against the order.
FAQ
The sheet lists 12V, 24V, 36V and 48V systems with automatic selection. Verify the battery chemistry and charging settings before connection, especially for lithium and custom battery banks.
1,040W at 12V, 2,080W at 24V, 3,120W at 36V, 4,160W at 48V. These are different battery-system ratings. Also check the array cold-weather open-circuit voltage, minimum operating voltage and the complete installation requirements.
No. 80A is the rated charging current. The supplied sheet separately lists 40A rated load/discharge current. Do not use the charge-current rating to size a load connected to the controller output.
Only with a suitable charging configuration. Obtain the battery manufacturer’s approved charge voltage and current, confirm BMS limits, and disable equalization where the battery requires it. Auto voltage detection alone does not establish lithium compatibility.
RS485 via RJ45 port. Confirm included accessories, protocol and monitoring software when placing the order; the presence of an RJ45 connector does not mean Ethernet networking.
No. It regulates PV charging into a DC battery bank and provides the listed DC load-control functions. Household AC loads need a suitable inverter and correctly designed protection and wiring.
Download the model PDF from this page. Send the required quantity, destination country, battery voltage and chemistry, panel Voc/Vmp/Isc and proposed string arrangement to info@patternbattery.com or use the enquiry form.
Related Products
MPPT Solar Charge Controllers
Explore PATTERN MRC 30–100A MPPT controllers for 12/24/36/48V battery systems. Compare the series, view photos and download the MRC brochure.
MPPT Solar Charge Controllers
PATTERN MRC-3048 30A MPPT solar charge controller for 12/24/36/48V batteries. View PV limits, load current, monitoring, product photos and PDF datasheet.
MPPT Solar Charge Controllers
PATTERN MPK7-6048 60A MPPT solar charge controller for 12/24/36/48V batteries. View PV limits, load current, monitoring, product photos and PDF datasheet.
MPPT Solar Charge Controllers
PATTERN MPK7-10048 100A MPPT solar charge controller for 12/24/36/48V batteries. View PV limits, load current, monitoring, product photos and PDF datasheet.

Reliable products, factory supply and technical support for local distributors and installers.
Become Our Distributor